Newman’s work closely with many councils across London carrying out Structural Repairs including the design and installation of repairs using the comprehensive range of Twistfix remedial solutions.
We were called upon to investigate cracking to elderly residents bungalows which had shown signs of ground movement. Newman’s were asked to design a solution that would restrain further movement.
The councils own engineers had been monitoring the movement using crack pins and the property had been stable for a period of 12 months indicating that underpinning or piling in the first instance was not necessary.
Masonry Beams were installed which will distribute the loads across the existing masonry effectively creating lintels within the bed joint. Twistfix are the only helical bar distributor that have had BRE test results and using their test data we are able to design a suitable solution for all structural repair projects.
With local cracks repaired using crack stitches and grout injection combined with the bed joint reinforcement it is unlikely that cracking will occur unless there is substantial ground movement which will be remotely monitored.
The full case study will be coming soon, in the mean time if you have any cracks that require a structural survey be sure to contact London’s leading structural repair contractor today on 0333 444 0154
Newman’s were instructed by City Line Construction, who are a reputable general building company, who we have worked closely with carrying out Structural Repairs for previously.
Whilst City Line were carrying out refurbishment works to this property in Fulham, South West London they discovered severe live cracks to the bay window and Newman’s were asked to carry out a Structure Only Reportto diagnose the cause of cracking and to design aBay Window Restraintspecification.
Being Trusted Twistfix approved contractors we have access to their range of remedial products and were able to design a specification which would be approved by Twistfix in order to provide a 10 year insurance backed guarantee.
Bed Joint Reinforcement was installed to distribute structural loads along with Twistfix Patented 450mm CD pinning ties. Combined with areas of resin injection and reinforcement we were able to restrain any further movement and provide a lasting repair solution.
the full case study is available on our case studies section with more information and photographs.
If your bay window needs restraining or you have noticed cracks to the internal or external masonry or separation of the wall and skirting board be sure to contact your nearest office today on 0333 444 0154 or email enquiries@newmans.com
We have once again been asked to carry out Structural Surveys in Canterbury, the two properties assessed today are suffering from very similar structural defects.
This property has been affected by recent lateral movement due to the masonry having no connection with the floor joists and internal walls, an attempt had been made at some point to rectify the defect by installing traditional tie bars however up on further investigation the tie bars were found to be of little help with a very poor connection to the property.
The property was also showing signs of very early lintel failure which is caused when the external brickwork above the brick arch lintel cracks and the lintel drops.
Newman’s structural repair surveyors work with both modern and traditional techniques to overcome building and structural defects. lateral restraint issues are repaired using Twistfix lateral restraint ties combined with Twistfix helical masonry beams.
Brick arch lintel failure can often be repaired without the need for costly rebuilding, once again Twistfix helical masonry beams combined with pinning ties and grout injection ensure all repairs are lasting. Making good using traditional materials and techniques ensuring a close to invisible repair.
To find out how we can help with your Structural defects contact out head office 0333 444 0154 or email enquiries@newmans.com