Structural Survey

Structural Repairs, What Should you expect from a competent contractor?

Structural Repairs, are not a common concern for many home owners and often most people tend to not know as much about the industry or the methods of Structural Repairs available.

Most have required the local builder, plumber or electrician to carry out some form of repairs, but when cracks appear and the words ‘structural damage’ ‘structural failure’ ‘could fall down’ are heard panic sets in.

Read more…

Author: Jon Newman
Posted:
Categories: Building and Structural Repairs, Crack Diagnosis

Parapet Wall Repairs

parapet-wall

Parapet Walls are a common feature of many Victorian and Georgian properties in London and Newman’s are often asked what their purpose is and why has mine fallen into a state of disrepair how do I fix it?

Parapet walls came into fashion in the early 18th century when the building act of 1707 was put into place and banned the use of timber projecting eaves in London as they posed a major fire risk so it became common practice to build a brick parapet that projected above the roof giving the building a flat roof look with a slated gable behind the parapet ring.

Read more…

Author: Jon Newman
Posted:
Categories: Building and Structural Repairs, Victorian Property Information

Bay Window Restraint Completed

Newman’s were instructed by City Line Construction, who are a reputable general building company, who we have worked closely with carrying out Structural Repairs for previously.

Whilst City Line were carrying out refurbishment works to this property in Fulham, South West London they discovered severe live cracks to the bay window and Newman’s were asked to carry out a Structure Only Report  to diagnose the cause of cracking and to design a Bay Window Restraint specification.

Bay Window Repairs
Bay Window Repairs

Being Trusted Twistfix approved contractors we have access to their range of remedial products and were able to design a specification which would be approved by Twistfix in order to provide a 10 year insurance backed guarantee.

Bay Window Crack
Bay Window Crack

Bed Joint Reinforcement was installed to distribute structural loads along with Twistfix Patented 450mm CD pinning ties. Combined with areas of resin injection and reinforcement we were able to restrain any further movement and provide a lasting repair solution.

Completed Project
Completed Project

the full case study is available on our case studies section with more information and photographs.

If your bay window needs restraining or you have noticed cracks to the internal or external masonry or separation of the wall and skirting board be sure to contact your nearest office today on 0333 444 0154 or email enquiries@newmans.com

Author: Jon Newman
Posted:
Categories: Building and Structural Repairs, Case Study