Lintel Failure, Lintel Reinforcement, The Modern Way….
One of the most common causes of cracked brickwork in London is caused by Lintel Failure and around 75% of residential Structural Repairs that we carry out are to Reinforce Failed Lintels.
enquiries@newmans.com
Newman Building Solutions – Case Studies relating to crack diagnosis.
One of the most common causes of cracked brickwork in London is caused by Lintel Failure and around 75% of residential Structural Repairs that we carry out are to Reinforce Failed Lintels.
Newman’s works closely with many councils across the South of England and have recently carried out a series of Structural Repair schemes to restore failed social housing under the decent homes scheme from our South West office in Bristol.
As part of the Structural Repair works we carried out a Structural repair Survey in order to diagnose the causes of cracking and movement and to design a suitable repair scheme that would restraint all Structural Movement.
The first phase of works are to 5 No 1940’s built properties built using cavity wall construction which were suffering from cracks at the junctions of the outside walls and the internal masonry partition walls.
In order to prevent any further movement we specified Twistfix Helical rods to be installed into the external bed joints, drilled into the internal masonry partition walls and then grouted into the masonry creating an L shaped tie resisting any further outward movement.
The Structural Repair works are carried out in just a matter of days including the installation of helical ties, re-plastering and re-pointing.
All the works are gauranteed by ourselves and also covered by a 10 year insurance back guarantee from Insured Guarantees Limited.
If you works on social housing schemes be sure to contact us today for all of your structural repair requirements.
enquiries@newmans.com or call on 0333 444 0154
Horizontal cracking to the external masonry of a property that is of cavity construction indicates a serious structural defect which will need to be investigated by a specialist.
In the most common instances short horizontal cracks within the mortar bed will indicate that the wall ties have failed and are suffering from oxidisation.
With a failure in the wall tie caused by corrosion iron oxide layers build up on the tie increasing the ties mass, lifting the brick which separates the brick from the mortar it was laid on to therefore the connection between the internal skin of masonry and the external skin of masonry is lost leaving the potential for collapse of the masonry which has happened.
If you have horizontal cracking to the external skin of masonry you should initially contact a wall tie specialist like ourselves and have an intrusive Wall Tie Survey carried out so that the cause of the cracking can be diagnosed and a suitable repair scheme implemented.
Wall Tie Replacement is a delicate process which although appears simple should not be deemed so. Many Wall Tie replacement contractors come and go usually due to poor workmanship and incompetence so always use a reputable company.
Newman’s are approved by the manufacturer Twistfix to design and install replacement Wall Tie schemes which we can guarantee for up-to 25 years. We specialise in Wall Tie Replacement and have designed and implemented many schemes.