Lateral Movement is a common Structural Defect in period properties and should be assessed and rectified using a Specialist Structural Repair Contractor.
Newman’s carry out many Structural Surveys and Structural Repairs to restrain and repair Lateral Movement, Bowing Walls and Bulging Stonework that has the potential to collapse a building if left ignored.
Newman’s were instructed by City Line Construction, who are a reputable general building company, who we have worked closely with carrying out Structural Repairs for previously.
Whilst City Line were carrying out refurbishment works to this property in Fulham, South West London they discovered severe live cracks to the bay window and Newman’s were asked to carry out a Structure Only Reportto diagnose the cause of cracking and to design aBay Window Restraintspecification.
Being Trusted Twistfix approved contractors we have access to their range of remedial products and were able to design a specification which would be approved by Twistfix in order to provide a 10 year insurance backed guarantee.
Bed Joint Reinforcement was installed to distribute structural loads along with Twistfix Patented 450mm CD pinning ties. Combined with areas of resin injection and reinforcement we were able to restrain any further movement and provide a lasting repair solution.
the full case study is available on our case studies section with more information and photographs.
If your bay window needs restraining or you have noticed cracks to the internal or external masonry or separation of the wall and skirting board be sure to contact your nearest office today on 0333 444 0154 or email enquiries@newmans.com
Newman’s were called upon by a home owner in East London who had discovered diagonal cracking and substantial rotation to the brick arch lintels to the rear of the property causing substantial concern.
With our Head office in Hammersmith, West London a surveyor was able to attend site on short notice to carry out a Structural Survey and diagnose the cause of cracking.
Lintel Failure was diagnosed after the replacement of the original load bearing timber frames which caused the lintel above the frame, supported mainly by the timber window, to drop.
In order to restore the masonry TwistfixBed Joint Reinforcement was installed to create masonry beams within the structure which distribute the structural loads across the masonry and create a reinforced beam alleviating the need for all the lintels to be rebuilt.
In very few instances it is not possible to save the lintel as the damage is to severe and a rebuild is the only option. Luckily for our client all of our technicians are time served in both traditional and modern methods of masonry repair.