failed lintels

Cracks Above Window and Door Openings

Diagonal cracks above window openings and door openings are common structural defects that show signs of movement which will need to be rectified.

Diagonal Cracking Above Opening
Diagonal Cracking Above Opening

Diagonal stepped cracking often indicates that the lintel that supports the masonry above the opening has failed. There are many types of lintels available and in use such as brick arch and soldier course lintels commonly found in period properties. Newer lintels are normally steel Catnic type lintels which can also fail showing signs of diagonal cracking above the opening.

Diagonal Cracking Above Opening
Diagonal Cracking Above Opening

In many instances the threat of collapse is over looked and simply ignored, in some cases cracks are raked out and repointed but if further movement was to occur the already compromised lintel could in theory collapse bringing the masonry above it crashing down as well.

Diagonal Cracking Above Opening
Diagonal Cracking Above Opening

Lintel Failure often occurs upon the removal of hardwood windows that were originally designed to bear a substantial load without distorting and are replaced with standard uPVC windows which are non-load bearing allowing the lintel to drop or bow causing sagging of the lintel which is shown by the diagonal stepped cracking.

Traditional methods are to remove the lintel and rebuild it, this is an intrusive method of repair and a slow process typically taking around a day to properly remove and replace a lintel.

Lintels can now be repaired using the Twistfix Helical System by using their Bed Joint Reinforcement which effectively creates a new lintel within the existing masonry by remove the mortar within two bed joints above the lintel and inserting helical rods encompassed in grout to create a load bearing lintel which spreads the structural loads across the length of the bars preventing further sagging of the lintel.

Bed Joint Reinforcement Repairing Lintels
Bed Joint Reinforcement Repairing Lintels

With the patented Twistfix 9mm CD helical tie we are able to install 450mm long ties vertically through the masonry in the lintel and pin it into the masonry above. This method is a vast improvement on previous pinning methods which often required 16mm holes drilled through the lintel. We can now install these ties through just 6 or 7mm pilot holes.

This type of repair is a fast and effective method of repair which has been tried and tested with BRE approval. Newman’s can guarantee this type of repair for ten years as we are a member of IGL insurance which covers the consumer in the event that we cease trading.

Author: Jon Newman
Posted:
Categories: Crack Diagnosis

Lintel Failure, Lintel Repair

Lintels come in various designs and are constructed from different materials but all carry out the same task; to support a structure above them within an opening.

Lintel Failure is a common structural defect amongst properties of all ages and constructions and Newman’s regularly carry out lintel failure surveys in order to establish the extent of lintel failure and the risk it poses.

Lintel Failure London
Lintel Failure London

Lintel failure can lead to the collapse of the masonry it is supporting with catastrophic effect. Lintel failure is often recognised by diagonal stepped cracking which is similar to subsidence but should not be confused as subsidence.

Lintel Failure, Diagonal Cracking
Lintel Failure, Diagonal Cracking

Traditional methods of lintel repair are costly and time consuming with many builders believing the only way to restore the structural integrity is to remove the lintel prop the masonry above and rebuild it.

Using modern methods of repair Newman’s can repair lintels by installing Twistfix Helical rods installed in the bed joint above the lintel creating beams above which support the masonry. With fast curing resins lintels can be propped into their original position and fixed saving the aesthetics of the property and time and money.

Author: Jon Newman
Posted:
Categories: Lintel Failure

Structural Survey to Lintel failure in Cardiff south Wales

Structural Survey to investigate a failed lintel at this property in Cardiff South Wales, our repair solution includes a combination of Twistfix helical bars and cementitious grout together with spa render repairs providing a permanent solution thus avoiding costly traditional rebuilding methods, Newman’s are designers and installers of modern day methods of building and structural repairs, for more information on how we can help contact us on 0333 444 0154

Failed Lintel Repairs
Failed Lintel Repairs

Author: Jon Newman
Posted:
Categories: Building and Structural Repairs, Lintel Failure, Surveys