Victorian Building

Bay Window Restraint Completed

Newman’s were instructed by City Line Construction, who are a reputable general building company, who we have worked closely with carrying out Structural Repairs for previously.

Whilst City Line were carrying out refurbishment works to this property in Fulham, South West London they discovered severe live cracks to the bay window and Newman’s were asked to carry out a Structure Only Report  to diagnose the cause of cracking and to design a Bay Window Restraint specification.

Bay Window Repairs
Bay Window Repairs

Being Trusted Twistfix approved contractors we have access to their range of remedial products and were able to design a specification which would be approved by Twistfix in order to provide a 10 year insurance backed guarantee.

Bay Window Crack
Bay Window Crack

Bed Joint Reinforcement was installed to distribute structural loads along with Twistfix Patented 450mm CD pinning ties. Combined with areas of resin injection and reinforcement we were able to restrain any further movement and provide a lasting repair solution.

Completed Project
Completed Project

the full case study is available on our case studies section with more information and photographs.

If your bay window needs restraining or you have noticed cracks to the internal or external masonry or separation of the wall and skirting board be sure to contact your nearest office today on 0333 444 0154 or email enquiries@newmans.com

Author: Jon Newman
Posted:
Categories: Building and Structural Repairs, Case Study

Structural Repairs,Working With Shop Fitting Contractors

Newman’s have been working with various shop fit out specialist carrying out Structural Repairs that are often unforeseen and have potential to delay that strict deadlines that these contractors must meet.

Structural Repairs
Structural Repairs

Newman’s offer an unrivaled service across London and the South East for contracts of this type and in most cases a surveyor is on site with in 24 hours of initial contact to carry out a Structural Assessment in order to design and implement a Structural Repair strategy.

Once our surveyor had carried out a Structural Survey it was discovered that there was numerous causes of concern which were highlighted by some major cracking and bowing to the masonry. A Structural Repair program was designed introducing Twistfix Lateral Restraint Ties, Bed Joint Reinforcement and water repellent masonry facade protection.

Structural Repairs
Structural Repairs

Lateral Restraint Ties were installed to the gable elevation were Bowing Masonry at floor joist level was apparent, Lintel Failure had also occurred and Bed Joint Reinforcement was used to create masonry beams without the need for costly rebuilds.

Lateral Restraint Ties
Lateral Restraint Ties

Water penetration to the front elevation had caused a failure to the pointing and spalling of the brick faces. Newman’s carry out deep bed re pointing and inject the masonry with Twistfix WHO-60 grout prior to re-pointing. The spalled bricks were repaired and tinted combined with Water Repellent facade cream which provides a breathable water resistant barrier the facade was saved.

 

The full case study and pictures will be live in our case studies section very soon.

Author: Jon Newman
Posted:
Categories: Bowing Walls, Building and Structural Repairs, Current Projects